Medical Imaging

Verify robustness of medical image classifiers and segmentation networks against clinically relevant perturbations. Based on the SPIE 2025 tutorial materials.


What You Will Learn

  • How to verify 2D medical image classifiers (single CT/MRI slices)

  • How to verify 3D volumetric classifiers using VolumeStar

  • How to model clinically relevant perturbations (bias field, gamma, noise)

  • The three-stage verification pattern for efficient analysis

Background

Medical imaging models must be robust to real-world imaging variations that occur during clinical acquisition – scanner noise, MRI bias field inhomogeneity, and contrast/brightness changes. Unlike adversarial attacks in computer vision, these perturbations are physically motivated and have specific mathematical characterizations.

Three-Stage Verification Pattern

The SPIE 2025 tutorial uses a three-stage approach for efficient verification:

  1. Check original: Ensure the network correctly classifies the unperturbed image

  2. Bounds check: Evaluate the network on the lower and upper bound images

  3. Full reachability: Only run the expensive analysis if stages 1-2 pass

This avoids wasting computation on images that are already misclassified or trivially non-robust.

2D Classification

Verify robustness of organ classification from single CT/MRI slices:

% Load network and test image
load('organ_classifier.mat');
net = matlab2nnv(trained_net);
img = test_images(:,:,:,1);
target = test_labels(1);

% Stage 1: Check original classification
y = net.evaluate(single(img));
[~, pred] = max(y);
if pred ~= target
    fprintf('Original image misclassified. Skipping verification.\n');
    return;
end

% Stage 2: Create perturbation set and check bounds
epsilon = 0.02;   % L-inf perturbation
lb = max(single(img) - epsilon, 0);
ub = min(single(img) + epsilon, 1);

y_lb = net.evaluate(lb);
y_ub = net.evaluate(ub);
[~, pred_lb] = max(y_lb);
[~, pred_ub] = max(y_ub);

if pred_lb ~= target || pred_ub ~= target
    fprintf('NOT ROBUST: Classification changes at perturbation bounds.\n');
    return;
end

% Stage 3: Full reachability analysis
IS = ImageStar(lb, ub);
reachOptions.reachMethod = 'approx-star';
result = net.verify_robustness(IS, reachOptions, target);

switch result
    case 1, fprintf('VERIFIED ROBUST under epsilon=%.3f.\n', epsilon);
    case 0, fprintf('NOT ROBUST.\n');
    case 2, fprintf('UNKNOWN (try smaller epsilon or exact-star).\n');
end

3D Volumetric Classification

For 3D medical images (MRI volumes, CT scans), use VolumeStar:

% Load 3D network and volume
load('volume_classifier.mat');
net = matlab2nnv(trained_net);
volume = test_volumes(:,:,:,:,1);   % H x W x D x C

% Create VolumeStar (4D perturbation set)
epsilon = 0.01;
lb_vol = max(single(volume) - epsilon, 0);
ub_vol = min(single(volume) + epsilon, 1);
VS = VolumeStar(lb_vol, ub_vol);

% Verify
reachOptions.reachMethod = 'approx-star';
output_sets = net.reach(VS, reachOptions);
[out_lb, out_ub] = output_sets.getRanges();

VolumeStar extends ImageStar to 4 dimensions (H x W x D x C), enabling verification of Conv3D and AveragePooling3D layers used in volumetric models.

Clinically Relevant Perturbations

Beyond L-inf noise, medical images are subject to specific acquisition artifacts:

Bias Field (MRI): Intensity inhomogeneity caused by RF coil sensitivity variations. The perturbation is spatially smooth and multiplicative.

% Bias field perturbation: multiplicative smooth field
% lb_bias and ub_bias define the range of bias field values per pixel
IS = ImageStar(img .* lb_bias, img .* ub_bias);

Gamma Correction (all modalities): Brightness/contrast variation from different display settings or scanner calibration.

% Gamma correction: img^gamma for gamma in [gamma_min, gamma_max]
lb_gamma = img .^ gamma_max;   % Lower bound (darker)
ub_gamma = img .^ gamma_min;   % Upper bound (brighter)
IS = ImageStar(lb_gamma, ub_gamma);

Random Noise (all modalities): Gaussian noise from sensor electronics, especially at high ISO or low-field MRI.

% Additive noise perturbation
IS = ImageStar(img - noise_bound, img + noise_bound);